Blume-Leiss

From AWF-Wiki
(Difference between revisions)
Jump to: navigation, search
(Handling)
Line 1: Line 1:
 
 
==General description==
 
==General description==
 
The Blume Leiss is developed to measure slope and [[tree height]] by [[the trigonometric principle]]. The device measures the elevation angle between the operator and measured points. Tree heights can directly be read from the device depending on fixed distances of 15m, 20m, 30m and 40m. For mountainous areas [[Fixed_area_plots#Slope_correction|slope correction]] factors can directly be read from the device depending on the slope.
 
The Blume Leiss is developed to measure slope and [[tree height]] by [[the trigonometric principle]]. The device measures the elevation angle between the operator and measured points. Tree heights can directly be read from the device depending on fixed distances of 15m, 20m, 30m and 40m. For mountainous areas [[Fixed_area_plots#Slope_correction|slope correction]] factors can directly be read from the device depending on the slope.
Line 92: Line 91:
 
* [[The trigonometric principle]]
 
* [[The trigonometric principle]]
 
* [[Bitterlich sampling]]
 
* [[Bitterlich sampling]]
+
{{Studienbeiträge}}
 
[[Category:Clinometer]]
 
[[Category:Clinometer]]

Revision as of 11:51, 4 December 2012

Contents

General description

The Blume Leiss is developed to measure slope and tree height by the trigonometric principle. The device measures the elevation angle between the operator and measured points. Tree heights can directly be read from the device depending on fixed distances of 15m, 20m, 30m and 40m. For mountainous areas slope correction factors can directly be read from the device depending on the slope. Figure 1 shows the front side of the device including:

  • example for the viewing while measuring distance with the levelling board,
  • the scales of height measurement for the fixed distances to the tree (15, 20, 30 and 40m) and
  • scale for slope measurement in °.


In this example the type of the device (BL6) has two buttons two separately lockable needles (figure 1), so that the height between the actor and the tree bottom/tree crown can directly be read. The difference between the measurements will be tree height –

\[ {h_t} = {h_c} - {h_b} \].

If the slope is larger than 5 degrees, the tree heights need to be corrected by the formula e*tan αi. This correction factor (CF) has to be multiplied with the tree height.



The optical rangefinder (figure 2) allows the user to measure the distance to the tree by mirroring a picture of the levelling board. Figure 2 shows the backside of the device where information is given about:

  • Height caluation
    • b-a=h (slope > 5° - viewing downwards)
    • a+b=H (slope < 5° - viewing horizontal)
    • a-b=h (slope > 5° - viewing upwards)
  • Correction factors
    • correction factor depending on slope in °
    • slope in ° depending on slope in %

Handling

Distance measurement

  1. Determine an optimal distance to the tree by checking the view field to tree bottom and top within the forest stand - preferably 15, 20, 30 or 40m,
  2. Place the leveling board at the tree,
  3. Find the correct fixed distance,
  4. Gauge the exact distance focusing the distance leveling board (figure 3b) and move closer or farther to the tree, till the top of the mirrored board is coincident with the corresponding mark on the leveling board - in this example, the mid mark of the leveling corresponds to a distance of 15m


Height measurement

  1. Focus the bottom of the tree (figure 4a) and lock the pendulum,
  2. Focus the top of the tree (figure 4b) and lock the second pendulum,
  3. The front side of the device (figure 1) shows two height values - the height can directly be derived by the formulas described above, depending on the slope
  4. Correct the derived height if necessary

Slope measurement

  1. Sight at the zero mark of the levelling board and lock the needle
  2. The slope in ° can directly be read from the scale (figure 1)



info.png Note:
When measuring with Blume Leiss, you need to observe the pendulum check mark to be sure, that the pendulum has stopped oscillating before locking the button. All scales are visible at once - be careful of taking the necessary scale.
Advantages Disadvantages
slope correction implemented dependance on fixed scales
optical distance measurement fixed distances to the tree (could be difficult in closed forest stands)
independence of power sources (no batteries needed) in dark forest stand optical measurement is difficult
no digital storage of measurement results available.